Marine & Safety Services
Offshore, vessel & platform electrical with full safety compliance.
Learn more →Complex offshore operations, upstream and downstream electrical infrastructure, and refinery electrical systems, engineered, installed and maintained by ATEX-certified, NEMSA-licensed professionals.
Nigeria's oil & gas sector accounts for over 85% of the nation's foreign exchange earnings (Source: NNPC), and every barrel of it moves through electrical infrastructure that must perform flawlessly in some of the harshest operating conditions on the planet. GDPS Ltd provides oil & gas electrical solutions across the full value chain: upstream flow stations and drilling rigs, midstream pipelines and terminals, and downstream refineries, gas plants and petrochemical facilities.
From our Port Harcourt headquarters, we support complex offshore operations in the Niger Delta, refinery electrical systems in the Port Harcourt-Warri corridor, and the new generation of mega-facilities like the Dangote Refinery in Lagos and NLNG Train 7 on Bonny Island. If your operation produces, processes or moves hydrocarbons in Nigeria, our licensed engineers keep your electrons flowing safely.
Upstream electrical systems live where failure is measured in deferred production, thousands of barrels per day. We design, install, and maintain:
Downstream facilities combine continuous processes with extensive hazardous areas, a combination that demands both technical depth and rigorous safety discipline. Our downstream scope includes refinery electrical system maintenance and upgrades, tank farm and depot electrification, loading gantry and metering skid electrics, and utility power distribution for process units. We support turnaround (TAR) scopes with 24/7 shift teams: switchgear overhaul, protection relay testing, motor refurbishment and pre-startup commissioning, the work that determines whether a restart hits its window or slips a costly week.
Hydrocarbon facilities are classified into hazardous zones, and electrical equipment in those zones is a primary ignition risk. Our engineers hold ATEX/IECEx competence certification and work across all protection concepts, Ex d flameproof, Ex e increased safety, Ex i intrinsic safety, Ex p pressurized. We maintain Ex equipment registers, perform grade A/B/C inspections, and remediate the degradation that tropical heat and humidity inflict on flamepaths, glands and enclosures. Every installation complies with IEC 60364, BS 7671, the Nigerian Electrical Code, and NUPRC (formerly DPR) safety guidelines, with documentation that stands up to any operator or regulator audit.
What should a credible inspection include? Ours deliver: infrared thermography of every accessible switchboard and termination; insulation resistance, earth loop impedance and RCD testing; protection relay secondary injection and grading verification; Ex equipment condition assessment against the hazardous area register; earthing and lightning protection testing; and a compliance gap report against NEMSA regulations and your own HSE standards. You receive a prioritized rectification plan, and if you choose, our teams execute the fixes under the same warranty-backed standards as all GDPS work.
As an indigenous company registered with the NCDMB, GDPS Ltd helps operators meet Nigerian Content Act requirements without compromising on technical quality. We invest in Nigerian engineers, Nigerian training, and Nigerian supply chains, and we deliver to the same IEC, IEEE and operator specifications applied on Egina FPSO, Bonga Southwest, Agbami and NLNG's Bonny Island trains. It is a combination the market asked for and too few contractors deliver: local content with zero compromise.
Whether you need an emergency crew on a flow station in Delta State tonight, a hazardous-area remediation program across your terminal, or a long-term electrical maintenance partner for your Lagos refinery operations, call GDPS Ltd. We answer 24/7, mobilize in 2 hours, and warranty every job.
When a critical low-voltage switchboard failed at a major refining facility in the Port Harcourt corridor, production across an entire process unit hung in the balance. The call reached GDPS at 02:14 on a Sunday.
Our emergency crew was on site before 04:00, isolated the fault to a catastrophic breaker failure compounded by degraded busbar insulation, and had a temporary bypass configuration safely energized by dawn, restoring the unit while permanent repairs proceeded. We sourced and installed a replacement ACB, re-torqued and tested all busbar joints, performed protection relay verification across the board, and thermographically surveyed the entire lineup under load.
Result: less than 6 hours of unit downtime against a worst-case multi-day outage, a permanent repair completed within the week, and a root-cause report the client's insurer accepted without query. The facility has since placed GDPS on a retained 24/7 emergency response contract.
A licensed engineer responds within 2 hours, 24/7.
Your details are protected under the Nigeria Data Protection Regulation (NDPR). We never share your information.
Offshore, vessel & platform electrical with full safety compliance.
Learn more →Industrial power systems, maintenance & factory electrification.
Learn more →